Ask an experienced pump operator what they pay most attention to and you will usually get the same answer: “The start and the end of the day.” Most problems during pouring come from a step skipped in the morning or cleaning left half-done in the evening.
Morning: before starting
- Hydraulic oil level: Low oil causes overheating and loss of output.
- Lubrication system: Make sure grease reaches the S valve and shaft bearings.
- Pipe connections: Are clamps closed and seals in place?
- Hopper grate: Must be in place and intact; a hopper without a grate is both a blockage and a safety risk.
- Water box: Filled with clean water? Cloudy water may be a sign of piston seal wear.
Before the first concrete: prime the line
Pumping concrete straight into a dry pipeline invites a blockage. The line must be wetted with a suitable lubricating slurry before concrete. The slurry leaves a thin film inside the pipes and stops the concrete sticking in the first metres.
During pouring
Always keep the hopper at a certain level; an empty hopper lets the pump draw air, and an overflowing one wastes concrete. During long waits, moving the concrete from time to time stops it setting in the line.
Evening: thorough cleaning
- Empty the remaining concrete from the hopper; wash the hopper and agitator.
- Clean the pipeline with a cleaning ball. Do not open pipes under pressure.
- Wash around the S valve, spectacle plate and cutting ring separately; slurry left there spoils the seal the next day.
- Empty the water box and refill it with clean water.
- In winter, leave no water in the system; see our winter guide.
Why is cleaning so important?
The S valve, spectacle plate, cutting ring and pistons are in contact with concrete every day. Slurry left on them works like sandpaper the next day. A well-cleaned pump gets far more life out of its wear parts.
When it is time to replace wear parts, see our S valves and shafts, concrete cylinders and pistons and hopper and grate categories, and request a quote with your pump model.
Safety: Do not open clamps while the line is under pressure. Nobody should stand at the outlet when the cleaning ball comes through.